WEDGE ANCHORS BOLT

dxlM6x45M6x60M6x70M6x80M6x90M6x100M6x110M6x120
H= drill ?66666666
L= drill depth5055555555555555
E= grip range215203040506070
G= torque0.7-10.7-10.7-10.7-10.7-10.7-10,7-10,7-1
L= thread depth2030303030303030
pull out-force:
200 kg concrete:900900900900900900900900
300kg concrete:1.4001.4001.4001.4001.4001.4001,4001,400
shear tension
200 kg concrete:1.0001.0001.0001.0001.0001.0001,0001,000
300kg concrete:1.0001.0001.0001.0001.0001.0001,0001,000
dxlm6x130m6x140m6x140m6x150m6x160m6x170m6x180m8x50m8x60
H= drill Ø666666688
L= drill depth555555555555554050
E= grip range809010011012013025
G= torque0.7-10.7-10.7-10.7-10.7-10,7-10,7-12-2,52-2,5
L1= thread Length303030303030302025
pull out-force:
200 kg concrete:90090090090090090090016001600
300kg concrete:1.4001.4001.4001.4001.4001.4001.4002.0002.000
shear tension:
200 kg concrete:1.0001.0001.0001.0001.0001.0001.0001.5001.500
300kg concrete:1.0001.0001.0001.0001.0001.0001.0001.5001.500
Grades
4,64,85,65,86,88,810,912,9A2
dxlM8x75M8x90M8x115M6x130M6x155M10x70M10x70M10x120
H= drill ?88888101010
L= drill depth6565656565657070
E= grip range2035607510052050
G= torque2-2,52-2,52-2,52-2,52-2,54-4,54-4,54-4,5
L= thread depth3030303030303030
pull out-force:
200 kg concrete:1.6001.6001.6001.6001.6002.4002.4002.400
300kg concrete:2.0002.0002.0002.0002.0002.9002.9002.900
shear tension
200 kg concrete:1.5001.5001.5001.5001.5002.4002.4002.400
300kg concrete:2.4002.4002.4002.4002.4002.4002.4002.400
dxlM10x150M10x170M10x210M10x230M12x155M10x70M10x70M10x120
H= drill ?1010101012121212
L= drill depth7070707060758585
E= grip range801001501702103060
G= torque4-4,54-4,54-4,54-4,57,87,87,87,8
L= thread depth3030303030454545
pull out-force:
200 kg concrete:2.4002.4002.4002.4004.0004.0004.0004.000
300kg concrete:2.9002.9002.9002.9004.7004.7004.7004.700
shear tension
200 kg concrete:2.4002.4002.4002.4003.8003.8003.8003.800
300kg concrete:2.4002.4002.4003.8003.8003.8003.8003.800
Grades
4,64,85,65,86,88,810,912,9A2
dxlM12x160M12x180M12x220M12x250M14x80M14x100M14x120M14x145
H= drill ?1212121214141414
L= drill depth858585856585100100
E= grip range801001401702103055
G= torque7-87-87-87-811-1311-1311-1311-13
L= thread depth4545454530454545
pull out-force:
200 kg concrete:4.0004.0004.0004.0004.8004.8004.8004.800
300kg concrete:4.7004.7004.7004.7005.5005.5005.5005.500
shear tension
200 kg concrete:3.8003.8003.8003.8004.5004.5004.5004.500
300kg concrete:3.8003.8003.8003.8004.5004.5004.5004.500
dxlM14x170M14x220M14x250M16x90M16x125M16x145M16x175M16x220
H= drill ?1414141616161616
L= drill depth10010010075110110110110
E= grip range801301602103055115
G= torque11-1311-1311-1314-1614-1614-1614-1614-16
L= thread depth4545453045454545
pull out-force:
200 kg concrete:4.8004.8004.8005.5005.5005.5005.5005.500
300kg concrete:5.5005.5005.5006.7506.7506.7506.7506.750
shear tension
200 kg concrete:4.5004.5004.5006.6006.6006.6006.6006.600
300kg concrete:4,5004.5004.5006.6006.6006.6006.6006.600
Grades
4,64,85,65,86,88,810,912,9A2
dxlM16x250M16x280M20x120M20x170M20x220M20x270
H= drill ?161614161616
L= drill depth100100105135135135
E= grip range13516524090140
G= torque14-1614-1628-3228-3228-3228-32
L= thread depth454545454545
pull out-force:
200 kg concrete:5.5005.5007.8007.8007.8007.800
300kg concrete:6.7506.7509.3009.3009.3009.300
shear tension
200 kg concrete:6.6006.60010.20010.20010.2006.600
300kg concrete:6.6006.60010.20010.20010.20010.200
Grades
4,64,85,65,86,88,810,912,9A2